After the interfaces connecting two devices are added to an E-Trunk, association between the interface status and BFD becomes abnormal.

Trouble Ticket Number

DTS2024112801696

Symptom

After the interfaces connecting two devices are added to an E-Trunk, association between the interface status and BFD becomes abnormal.

Condition

The interfaces connecting two devices are added to an E-Trunk, and association between the interface status and BFD is configured.

Impact

The BFD status is abnormal.

Severity

Minor

Root Cause

An error occurs in BFD processing.

Solution

The error is fixed.

Solution Impact

N/A

Problem Resolved in

V300R023C00SPC100

Involved Models

AR6140 series (except the AR6140-16G4XG)

Precaution

STP must be disabled on interfaces on which multicast BFD is configured.